Airnet® II and II (s)

Airnet® II and II (s)

  • Manufacturer: PMS - Mỹ
    Model: Airnet® II and II (s)
    Document: Airnet II Stainless Steel_-27-10-2023-13-33-21.pdf
    • Request a quote Request a Quotation
  • Contact

Airnet® II / IIs Remote Particle Sensors (2 Channels) 

Airnet Remote Particle Sensors: 2 Channels. As part of a facility monitoring solution, the Airnet® II and IIs Particle Sensors from Particle Measuring Systems meet the specifications of ISO 21501-4 to measure the size and number of particles suspended in the air for real-time monitoring of defect-causing particles.
2 channels model for  0.5 and 5.0 μm size range, suitable for Pharmaceutical application
1.0 CFM flow rate. Communication with Modbus TCP IP. Standard POE for communication & power requirements. Although, optional 4-20 mA output (Polycarbonate version only). Available in chemical-resistant polycarbonate (PC) or Stainless Steel 316L enclosure. Optional XR coating protects sensors against corrosive or oxidizing vapours in VHP sterilization processes with Airnet II XR models.

Sensitivity range: 0.3 - 5.0 µm - 2 Channels, Annex 1 solution

As part of a facility monitoring solution, the Airnet® II and IIs Particle Sensors from Particle Measuring Systems are an EU GMP Annex 1 solution that meets the specifications of ISO 21501-4 to measure the size and number of particles suspended in the air for real-time monitoring of defect-causing particles.

simple and cost-effective way to monitor your cleanroom, the Airnet II Air Particle Sensor provides unparalleled performance with data transmission capabilities for remote monitoring.

Versatile power options combined with an ultra-small footprint make the Airnet II Air Particle Sensor easy to install right where you need it. The unit can be configured to accept distributed power from an in-house system, local power plugin (Polycarbonate version only), or Power over Ethernet (PoE).

Data integrity is maintained through the use of a data queue feature that continues to gather data even if communication is lost due to a power outage. To ensure proper flow conditions and vacuum system operation, these units incorporate a Dynamic Flow Sensing system that will alarm with a 15% change in flow conditions.

For situations where sampling is required during the vaporized hydrogen peroxide (VHP) sterilization process, an optional VHP-compatible unit is available for a simple installation without complex valving. Download the Airnet® 510 XR Resilience to Vaporized Hydrogen Peroxide app note.

Features:

  • 2 channels
  • 0.5 and 5.0 μm size range, suitable for Pharmaceutical application
  • 1.0 CFM flow rate
  • Modbus communications
  • Optional 4-20 mA output (Polycarbonate version only)
  • Chemical-resistant polycarbonate (PC) enclosure or Stainless Steel 316L
  • Low sample point cost
  • Small enough for use in remote locations
  • Includes system validation documentation

Benefits:

  • Proven technology provides reliable and accurate data
  • Allows for immediate reaction to particle contamination events
  • A low-cost solution for multipoint monitoring
  • Interfaces with Facility Net and FacilityPro Software for comprehensive management of cleanroom conditions
  • A small footprint and flexible mounting options make it easy to install in cleanrooms and mini-environments
  • A solid state laser diode (LD) drastically reduces the need for maintenance and extends product lifecycle
  • Data queue maintains data integrity when communication is lost
  • Optional 4-20 mA output for integration with existing systems to help you understand your environment and communicate with other systems (Polycarbonate version only)
  • Optional XR coating protects sensors against corrosive or oxidizing vapors in VHP sterilization processes

Applications:

  • Cleanroom monitoring
  • Dedicated monitoring of critical locations
  • Trend analysis
  • Statistical process control
  • Multi-location monitoring
  • Isolator monitoring
  • CONTACT US TODAY FOR  SUPPORT AND PRICING 

    SAO NAM - AUTHORIZED SALES AND SERVICE CENTER IN VIETNAM

    Head office: 92 Street 13, Binh Tri Dong B Ward, Binh Tan District, HCMC

    Hotline: (84.28) 6260 2704 / 090 393 8641 – Email: info@saonamchem.com

    Mobile phone : 0388199098 / 0902577792 - Website: https://www.saonamchem.com https://www.saonam.vn or https://www.pmsvietnam.vn

  • Commitment to quality
  • Genuine Warranty
  • Delivery
  • 24/7 SERVICE
DMCA.com Protection Status