LiQuilaz II E20

LiQuilaz II E20

  • Manufacturer: Particle Measuring Systems - Mỹ
    Model: LiQuilaz II E20
    Document:
    • Request a quote Request a Quotation
  • Contact

Particle counter for liquid: LiQuilaz E-20P (2-125 µm) or LiQuilaz E 15P (1.5-125 µm).

The LiQuilaz II E15P, E20, and E20P laser particle counters are volume-based monitors with a size sensitivity range of 1.5-125 µm.

The LiQuilaz II laser particle counter provides the same level of accuracy, reliability, and repeatability that customers have trusted for many years. The LiQuilaz II sensor has both RS-485 and Ethernet network communication capabilities. The new Ethernet capability increases the flexibility of the product and significantly simplifies installation.

The volume-based liquid particle counter provides the highest possible accuracy by measuring 100% of the sample volume, allowing for the use of short sampling times without compromising statistical significance.Máy đếm hạt laser LiQuilaz II- sao nam

Applications include:

  • Pharmaceutical industry for verifying PW performance
  • Checking cleanliness of medical equipment
  • Collecting injection samples
  • Detecting abrasive particles
  • Improving continuous sampling processes
  • Complying with USP 788-1788 with the SLS sampler

Specifications:

  • Size range: 2 – 125 µm
  • Flow rate: 20 ± 10% ml/min
  • Sample volume: Volumetric 20 ml/min (100%)
  • Channel size: User adjustable from 1 to 15
  • Resolution: Below 10% at 10 µm
  • Maximum concentration: 10,000 particles/ml
  • Sample temperature: 50 – 122 °F (0 – 50 °C)
  • Counting zero: < 15 counts/liter
  • Pressure range: 0 - 100 psi
  • Laser source: Diode laser
  • Wetted surface materials: Fused silica, black quartz, Kalrez® and Kel-F®
  • Liquid connection: 3 mm hose barb or Flaretek® 1/4 inch
  • Dimensions (L x W x H): 32.4 x 10.8 x 11.4 cm
  • Weight: 6.1 lb (2.8 kg)
  • Rated voltage: 100 - 240 V, 50/60 Hz, 0.75 A
  • Communication mode: 5-wire, RS-485 connector, DE9, PMS serial communication protocol, Ethernet 10/100BaseT, PMS Ethernet communication protocol, Modbus TCP
  • Calibration solution: DI water
  • Direct and on-site calibration at customer's factory: Materials used can be traced back to the US National Institute of Standards and Technology (NIST) and/or the Japanese Industrial Standards (JIS)
  • Environment: Temperature: 50 – 95 °F (10 – 35 ºC); Humidity: non-condensing.

CONTACT US TODAY FOR  SUPPORT AND PRICING 

SAO NAM - AUTHORIZED SALES AND SERVICE CENTER IN VIETNAM

Head office: 92 Street 13, Binh Tri Dong B Ward, Binh Tan District, HCMC

Hotline: (84.28) 6260 2704 / 090 393 8641 – Email: info@saonamchem.com

Mobile phone: 0388199098 / 0902577792

Website: https://www.saonamchem.com https://www.saonam.vn or https://www.pmsvietnam.vn

  • Commitment to quality
  • Genuine Warranty
  • Delivery
  • 24/7 SERVICE
DMCA.com Protection Status